|
 |
|
 |

 |
The ink manifold
has a maximum height of 1.25”
above the cheekplate (fountain
end) and a width of 1.5”
which allows for quick plate changes
without having to remove the Ink
Leveler as well as providing easy
access to the ink fountain |

 |
The sensor
height above the cheekplate is
2.5” in it’s normal
vertical operating condition and
2” in auto shut-off mode
or horizontal position |

 |
Aluminum extruded
manifold and cheekplate brackets
|
 |
No scheduled
maintenance required |
| |
|
| |
|
|
 |
|
 |
| Power
Supply |
110/120/220/240
VAC
50/60 Hz ½
Amp fuse |
| Power
Consumption |
250
mA |
| Air
Requirements |
60
– 120 psi |
| Air
Consumption |
.002 scfm |
| Ink |
3000
psi ½”
NPT Ink Hose |
| Control
Box Dimensions |
4.5”
x 2.5” x 1.25” |
| Valve
Box Dimensions |
2.5”
x 2.5” x 16” |
| Sensor |
Capacitance |
| Options |
Ink
Filters, Shut-off
valves |
|
|
|
|
|